+86-136-52756687

The Last Line Of Defense: Dissmann Fuse MEV Series Fuse Is Applied To 360kW Rectifier Cabinet Product in Charging Pile

Feb 24, 2023

        Dissmann fuse is the main supplier of many domestic head charging pile enterprises in China, such as Star Charge, Sinexcel, CHARGECORE, EN+, HONGJIALI, etc. With the charging efficiency of charging pile products becoming higher and higher, the requirements for charging pile fuse are also higher and higher in terms of safety protection. Dissmann fuse has fully demonstrated its strong R&D strength and continuously met the requirements of charging pile manufacturers for temperature rise, breaking capacity, certification and cost of charging pile fuses. Through more than ten years of experience in the selection of charging pile fuses, we will provide more charging pile manufacturers with the most satisfactory, reliable and cost-effective charging pile fuses.

        Through the experience of selection of 360kW rectifier cabinet products in charging pile fuse of Star Charge, we will share with you.

Star Charge 360kw DC split unit PDU

Star Charge 360kw Split Unit -PDU

 

Star Charge 360kw DC split unit PDU-Dissmann MEV fuse application case

Dissmann MEV-J-D20 is applied to the 360KW PDU

How We choose the fuse for the 360KW PDU?

        First, confirm the working voltage of the fuse through the rated working voltage of the charging pile and the charging pile module. The working voltage of the fuse must be greater than or equal to the charging pile and the charging pile module. According to the parameters, determine that the 1000VDC charging pile fuse is required.

        Second,The rated current of the fuse is determined based on the maximum rated output current of the charging pile of 250A, and the rated current of the fuse is 1.5 times of the maximum rated output current of the charging pile (375A) after the correction of factors such as thermal connection, ambient temperature, air cooling, altitude, etc. Since the current distribution of fuse above 300A is mostly 300/315/350/400, Del Electronics recommends 400A fuse from the perspective of fuse service life and after many customer experiments. The fuse parameter index required for this charging post is 1000VDC 400A.

        Finally,according to the TUV certification, breaking capacity, installation method and the most important cost of the fuse, the MEV-J-D20-400 1000VDC 400A European bolt type installation fuse is recommended.

The protection category of the charging pile fuse is aR part protection, which will only act when the short circuit current occurs. The relay is required to protect the overload current, so the fuse is used together with the relay in the charging pile to comprehensively protect the charging pile from harmful current.

Dissmann fuse MEV-J-D20-400 Parameters

Rated Voltage

1000VDC

Breaking Capacity

50kA(Time Constant≤10ms)

Rated Current

400A

TUV Certification

No:B 113737 0001

Protection Type

aR

Installation

M10 bolt, recommended torque (21 ± 1) N · m

The structure and performance meet the requirements of GB13539, IEC60269, UL248, European Union and China RoHS directives and QC/T413, ISO8820 and JASOD622.

 

MEV-J-D20

 